Titanium versus Biodegradable Implants for Fracture Fixation: A Retrospective Comparative Study
Authors Ullah W, Shali A, Abulaiti A, Erlin C, Yusufu A
Received 28 November 2025
Accepted for publication 10 March 2026
Published 13 April 2026 Volume 2026:18 585068
DOI https://doi.org/10.2147/ORR.S585068
Checked for plagiarism Yes
Review by Single anonymous peer review
Peer reviewer comments 2
Editor who approved publication: Professor Qian Chen
Wajid Ullah,1 Aierbanjiang Shali,1 Alimujiang Abulaiti,1,2 Cheng Erlin,1,2 Aihemaitijiang Yusufu1,2
1Department of Trauma and Microreconstructive Surgery, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, People’s Republic of China; 2Xinjiang Key Laboratory of trauma Reconstruction, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang, People’s Republic of China
Correspondence: Aihemaitijiang Yusufu, Email [email protected]
Background: Titanium alloy implants are widely used in fracture fixation due to their excellent mechanical stability, but they often require secondary surgeries for removal. In contrast, biodegradable implants eliminate the need for removal, yet concerns regarding their mechanical strength in load-bearing bones remain. This study evaluates the clinical trade-off between mechanical rigidity and the burden of secondary surgery by comparing titanium versus biodegradable implants in limb and pelvic fractures.
Methods: A retrospective cohort study was conducted on 73 patients treated between November 2021 and August 2024. Patients were divided into the titanium group (n = 40, primarily diaphyseal fractures) and the biodegradable group (n = 33, primarily metaphyseal/peri-articular fractures). Outcomes including implant palpability and reoperation rates were assessed. A stratified analysis compared outcomes in weight-bearing versus non-weight-bearing fractures.
Results: The mean age of patients was 42.6 ± 16.03 years. Titanium implants were associated with significantly higher rates of plate palpability (18/40, 45.0% vs 3/33, 9.1%; OR 8.18, 95% CI 2.14– 31.3; P = 0.001) and secondary surgery (14/40, 35.0% vs 3/33, 9.1%; OR 5.38, 95% CI 1.39– 20.8; P = 0.012) compared to biodegradable implants. Elective removal due to discomfort occurred in 17.5% (7/40) of titanium patients but was eliminated (0%) in the biodegradable group (P = 0.014). In the weight-bearing subgroup, biodegradable implants significantly reduced palpability (11.1% vs 53.3%, OR 9.14) without increasing complication-driven reoperations. However, three cases (9.1%) of refracture occurred in the biodegradable group compared to zero in the titanium group (P = 0.088).
Conclusion: In this cohort, biodegradable implants were associated with a reduction in implant palpability and elective removal surgery for metaphyseal and peri-articular fractures. However, due to lower mechanical strength, titanium remains the preferred choice for diaphyseal fractures requiring high mechanical stability. These findings are limited by the retrospective design and heterogeneity of fracture sites.
Keywords: titanium implants, biodegradable implants, fracture fixation, plate palpability, secondary surgery
Introduction
Bone fractures are among the most common musculoskeletal injuries mainly result from pathological weakness and mechanical trauma.1 The global incidence of fractures is about 1% ~ 2%, of which limb fractures account for about 60% to 70%. For fractures accompanied by severe displacement that cannot achieve functional or anatomical alignment through manual reduction, surgical intervention is required. Open reduction and internal fixation (ORIF) using plates, screws or intramedullary nails remains the standard of care.2,3 Most upper and lower limb fractures take approximately 3 to 6 months or more to complete healing.4
Commonly used internal fixation implants include stainless steel implants, carbon fiber implants, titanium alloy, and biodegradable alloy.5 Titanium alloy implants are widely favored for their superior mechanical strength, biocompatibility and corrosion resistance. Compared with stainless steel implants, the flexibility of titanium alloy implants allows control of strain between debris and promotes bone healing.6 Titanium alloys demonstrated superior mechanical properties compared with carbon fiber implants.7 However, a significant clinical limitation of metallic fixation is hardware prominence, particularly in anatomical regions with thin soft tissue coverage (eg, the ankle or distal tibia). This frequently results in symptomatic palpability and discomfort, necessitating a secondary surgical procedure for implant removal.8 This second trauma increases the economic burden on the healthcare system and exposes patients to additional surgical risks.
These drawbacks of metallic implants have driven the introduction of biodegradable fixation systems, which are designed to provide temporary stability during the healing phase before being gradually absorbed by the body, thus eliminating the need for removal.9 Degradable implants are mainly composed of polyglycolic acid (PGA) and polylactic acid (PLA) often reinforced with magnesium alloys to enhance mechanical properties.10 Due to their excellent biocompatibility and reduced infection risks, they have been used for fracture fixation in non-weight-bearing areas such as the craniomaxillofacial skeleton.11,12 However, the application of degradable implants in load-bearing limb fractures remains controversial. Critics argue that biodegradable materials may possess insufficient mechanical strength to withstand weight-bearing forces, or exhibit unpredictable degradation rates that could compromise fracture stability.13
Therefore, the choice of titanium alloys and degradable implants involves a clinical trade-off between mechanical rigidity and the avoidance of secondary surgery. This study aims to evaluate this trade-off by comparing the clinical efficacy, complication rates, and reoperation burdens of titanium versus biodegradable implants. Furthermore, it seeks to address the controversy in long bone fixation by performing a subgroup analysis to compare outcomes in both weight-bearing and non-weight bearing fractures.
Methods
Study Design
This retrospective cohort study evaluates the outcomes of titanium (Group A) and biodegradable (Group B) plates and screws in patients with fractures of the upper limbs (metacarpal, phalangeal), lower limbs, or pelvis. Patients data were collected from Hospital HMIS system at the First Affiliated Hospital of Xinjiang Medical University from November 2021 to August 2024. Ethical approval was obtained from the Medical Ethical Committee of the First Affiliated Hospital of Xinjiang Medical University (Approval No. K202506-16). Due to the retrospective nature of the study, the requirement for informed consent for general data collection was waived by the ethics committee; however, specific written informed consent was obtained from all patients whose detailed case studies and radiographic images are presented in this manuscript. The biodegradable materials used in the study are composed of PLA/PGA with magnesium alloys.
Inclusion and Exclusion Criteria
Patients aged 18 years or older with closed fractures of the upper limb (metacarpal, phalangeal), lower limb, or pelvis requiring internal fixation were included in the study. Fractures were classified as simple (2 pieces), comminuted (3 pieces), or complex fractures (more than 3 pieces). Patients with open fractures, pathological fractures due to osteoporosis or malignancy, or those with systemic conditions such as chronic infections or uncontrolled diabetes that could affect bone healing were excluded. Additionally, patients who lost to follow-up before completing postoperative assessments were excluded from the study.
Surgical Procedure
All surgical procedures were performed by experienced orthopedic surgeons under either local intravenous anesthesia or general anesthesia, depending on the complexity of the fracture and patient condition. Preoperative planning involved detailed imaging, including anteroposterior and lateral radiographs, as well as 3D-CT reconstruction, to assess fracture displacement and guide the fixation strategy. A standard surgical approach was employed to expose the fracture site, ensuring careful preservation of the periosteal blood supply. Anatomical reduction of the fracture was achieved prior to fixation.
In the titanium group, fractures were stabilized using standard non-locking or locking titanium plates, which were carefully contoured to the bone surface. In the biodegradable group, fractures were fixed with biodegradable materials composed of PLA/PGA with magnesium alloys. To achieve anatomical contouring, the biodegradable plate was softened in a sterile saline bath (55–60°C) for approximately 10–20 seconds until malleable, molded to the patient-specific bony contour using a bending template and gentle broad-surface benders, and then allowed to cool to restore rigidity before definitive screw fixation. Repeated re-heating and excessive back-and-forth bending were avoided. Postoperatively, antibiotic prophylaxis and rehabilitation protocols were followed according to standard hospital guidelines, ensuring both groups received appropriate care to manage pain, prevent infection, and promote healing.
Postoperative Follow-Up and Assessment
For this retrospective study data regarding postoperative follow-up were collected for patients who had clinically followed up for minimum 6 months after surgery. Clinical data, including pain assessment, range of motion evaluation, and the detection of any signs of infection, implant failure, or other complications, were obtained through patient records. Pain scores (VAS/NRS) were recorded at each follow-up point to track pain severity over time. Radiographic healing was assessed at each time point, and secondary surgery was recorded based on implant failure or complications, including plate palpability, infection, and extrusion. The degradation process of biodegradable implants was monitored closely, particularly for signs of premature degradation that could affect implant stability. Data on adverse events related to biodegradable implants, such as inflammatory responses and premature loss of strength, were also tracked during the follow-up period. In cases where titanium implants caused discomfort or complications, implant removal was planned. For biodegradable implants, patients were monitored for the natural degradation process over time.
Statistical Analysis
All data were analyzed using SPSS 22.0 (IBM Corp, Armonk, NY). Continuous variables are presented as mean ± standard deviation (SD) and were compared using the Student’s t-test or Mann–Whitney U-test depending on normality. Categorical variables are presented as frequencies and percentages and were analyzed using the Chi-square test or Fisher’s exact test. To account for potential confounding due to fracture site heterogeneity, a stratified analysis was conducted based on weight-bearing status (weight-bearing vs non-weight-bearing) and fracture level. For key binary outcomes, Odds Ratios (OR) with 95% Confidence Intervals (CI) were calculated to estimate the magnitude of effects. A P-value of < 0.05 was considered statistically significant.
Results
Between November 2021 and August 2024, a total of 113 patients were initially screened for eligibility. Of these, 40 patients were excluded from the study. The reasons for exclusion included age under 18 years (n = 6), open fractures (n = 4), pathological fractures due to osteoporosis (n = 11), chronic active infection (n = 3), and uncontrolled diabetes (n = 4). Additionally, 12 patients were excluded due to loss of follow-up or incomplete medical records. The remaining 73 patients met all inclusion criteria and were included in the final analysis, divided into the titanium group (n = 40) and the biodegradable group (n = 33) (Figure 1).
|
Figure 1 Schematic flow diagram illustratining patient selection process. |
A total of 73 patients were included in the study, with a mean age of 42.6 ± 16.03 years. The majority were male 46 (63.9%) and 27 (37%) were female. The titanium group consisted of 40 patients (60% male and 40% female), while the biodegradable group consist of 33 patients with a gender distribution (66.6% male, 33.4% female). The mean ages were comparable between the two groups (42.9 ± 15.9 years vs 43.1 ± 15.7 years, respectively) with no significant difference (P = 0.53). In terms of comorbidities, 9.6% of patients in the overall cohort had hypertension and 2.7% were diabetic. In titanium group, 12.5% of patients had hypertension and 5% were diabetic while in the biodegradable group 6.06% had hypertension with no diabetic patient. Neither of these differences was statistically significant (P = 0.59 and P = 0.56, respectively). Alcohol consumption was reported by 41.1% of patients overall, with 37.5% in the titanium group and 45.45% in the biodegradable group. Similarly, 53.4% of the cohort were classified as smokers, with 37.5% in the titanium group and 57.6% in the biodegradable group. Regarding BMI, the overall cohort had an average BMI of 26.23 ± 3.91 kg/m2, with 39.7% classified as overweight and 26.0% as obese. In the titanium group 37.5% were overweight and 20.0% were obese, while in the biodegradable group, 42.4% were overweight and 33.3% were obese. In terms of pain severity, 57.5% of titanium patients reported severe pain compared with 39.4% in the biodegradable group while moderate pain was reported by 37.5% and 39.4%, respectively. Mild pain was more common in the biodegradable group (21.2%) compared to the titanium group (15.0%, P = 0.30) (Table 1).
|
Table 1 Characteristics of Study Participants by Implant Type |
The mechanism of injury differed significantly between the two groups (P = 0.012). Falls were the leading cause of fracture in the titanium group (70.0%), whereas the biodegradable group showed a more diverse injury profile, with a significantly higher proportion of trauma-related injuries (27.3% vs 5.0%) and sports injuries (9.1% vs 0.0%). Car accidents accounted for a similar proportion of cases in both the titanium (22.5%) and biodegradable (21.2%) groups. Regarding anatomical distribution, detailed analysis revealed distinct patterns in fracture location and level. In the upper limb, clavicle fractures were predominantly treated with titanium implants (n = 8) compared to biodegradable implants (n = 1), while biodegradable implants were more frequently utilized for fractures of the radius, ulna, and hand (n = 6 vs n = 0 in the titanium group). In the lower limb, the titanium group was characterized by a high prevalence of tibial shaft fractures (n = 27), whereas the biodegradable group showed a strong predilection for ankle and malleolar fractures (n = 12). Primary pelvic fractures were treated exclusively in the biodegradable group (n = 2, 6.1%). A statistically significant difference was observed in the fracture level (P = 0.003), reflecting the distinct biomechanical indications for each implant type. Titanium implants were primarily used for diaphyseal (shaft) fractures (57.5%), particularly in the tibia. In contrast, biodegradable implants were significantly more likely to be selected for metaphyseal, epiphyseal, or peri-articular fractures (84.8%), such as those involving the ankle, distal radius, or pelvis, where avoiding secondary removal is clinically advantageous. Table 2 represents characteristics of the fractures.
|
Table 2 Characteristics of Fractures |
Operative and hospitalization parameters are detailed in Table 3. There were no statistically significant differences between the two groups regarding surgical trauma or complexity. The mean operative time was comparable between the titanium (138.9 ± 58.0 min) and biodegradable (131.4 ± 54.7 min) groups (P = 0.571). Similarly, intraoperative physiological stress appeared consistent, with no significant differences observed in intraoperative blood loss (83.8 ± 98.5 mL vs 94.2 ± 115.5 mL, P = 0.676) or the volume of intraoperative fluid infusion (1087.5 ± 451.3 mL vs 1242.4 ± 532.1 mL, P = 0.183). However, a highly significant difference was observed in the implant hardware burden (P < 0.001). Patients in the titanium group required a significantly higher number of screws for fixation (mean 10.6 ± 4.3; range 4–22) compared to the biodegradable group (mean 6.3 ± 1.8; range 4–10). Regarding postoperative recovery, the mean length of hospital stay was shorter in the biodegradable group (10.1 ± 4.2 days) compared to the titanium group (12.4 ± 7.8 days), though this difference did not reach statistical significance (P = 0.136).
|
Table 3 Operative Characteristics and Hospitalization Data |
Clinical outcomes are summarized in Table 4. Regarding bone healing, satisfactory clinical and radiographic consolidation was observed in all patients across both groups. While specific time-to-union intervals were not standardized due to the retrospective nature of the study and varying fracture patterns (eg, tibial shaft vs ankle), union was confirmed in all patients during their follow-up visits. Although the mean follow-up duration was significantly shorter in the biodegradable group (7.9 ± 2.4 months) compared to the titanium group (18.6 ± 6.6 months), this observation period was sufficient to confirm union and the absence of early mechanical failure in the biodegradable cases. A significant difference was observed in implant palpability/discomfort, which was reported by 45.0% of patients in the titanium group compared to only 9.1% in the biodegradable group (Table 4; P = 0.001, OR 8.18). Consequently, the overall rate of secondary surgery was significantly higher in the titanium group (35.0% vs 9.1%, P = 0.012).
|
Table 4 Clinical Outcomes and Complications |
Crucially, Table 4 clarifies the indications for these reoperations. Elective removal due to implant discomfort accounted for half of the secondary surgeries in the titanium group (17.5%). When the analysis was restricted to complication-driven reoperations (eg, infection, fixation failure), there was no statistically significant difference between titanium (17.5%) and biodegradable (9.1%) implants (P = 0.496).
To address potential confounding by fracture type, a stratified analysis based on weight-bearing status was performed (Table 5). In the weight-bearing subgroup (lower limb and pelvis), titanium implants were associated with significantly higher odds of plate palpability compared to biodegradable implants (53.3% vs 11.1%, P = 0.001, OR 9.14). Furthermore, while the overall reoperation rate showed a trend toward being higher in the titanium group (30.0% vs 11.1%, P = 0.096), the difference was driven by elective procedures. Specifically, elective removal due to discomfort was significantly more frequent in the titanium group (20.0% vs 0.0%, P = 0.028). In contrast, there was no significant difference in complication-driven reoperations between the two groups in the weight-bearing cohort (10.0% vs 11.1%, P = 1.000). Among non-weight-bearing fractures (upper limb), there were no statistically significant differences in palpability (20.0% vs 0.0%, P = 0.491) or secondary surgery (50.0% vs 0.0%, P = 0.052). However, it is notable that no patient in the biodegradable non-weight-bearing group required reoperation for any reason. Secondary analysis of intraoperative parameters revealed that implant type influenced the hardware burden regardless of fracture location. Titanium implants required a significantly higher number of screws in both the weight-bearing (11.0±4.2 vs 6.6±1.8, P < 0.001) and non-weight-bearing subgroups (9.2±4.6 vs 5.6±1.9, P = 0.043). However, other surgical parameters were comparable across subgroups. There were no significant differences in intraoperative blood loss (P = 0.898 for weight-bearing; P = 0.178 for non-weight-bearing) or surgical time (P = 0.369 for weight-bearing; P = 0.519 for non-weight-bearing). A trend toward shorter hospital stay was observed in the biodegradable weight-bearing group (10.2 vs 13.2 days), though this did not reach statistical significance (P = 0.068).
|
Table 5 Stratified Analysis of Clinical Outcomes by Weight-Bearing Status |
Perioperative management and follow-up data are summarized in Table 6. The majority of patients in both groups underwent surgery under spinal or epidural anesthesia (60.0% in the titanium group and 45.5% in the biodegradable group), with no statistically significant difference in the distribution of anesthesia methods (P = 0.161). Postoperative pain control was also comparable between the groups; there was no significant difference in the proportion of patients reporting mild, moderate, or severe pain grades (P = 0.305).
|
Table 6 Perioperative Management and Follow-up |
However, a significant difference was observed in the follow-up duration (P < 0.001). The titanium group had a significantly longer mean follow-up period (18.6±6.6 months) compared to the biodegradable group (7.9 ± 2.4 months). This difference reflects the earlier adoption of titanium implants in our practice, whereas biodegradable implants represent a more recent introduction.
Typical Case
Typical Case 1
A 49-year-old male patient presented with fractures of the right tibial shaft and fibula, treated with ORIF using a titanium alloy plate and screws. Postoperative X-rays confirmed correct anatomical alignment and stable fixation. At the 6-month follow-up examination, no signs of complications were observed at the surgical site. The patient’s postoperative pain and swelling gradually subsided, with excellent recovery (Figure 2).
Typical Case 2
A 42-year-old female patient presented with multiple pelvic fractures, including a left iliac fracture and left superior/inferior pubic rami fractures, treated with ORIF using biodegradable plate and screws. Postoperative X-rays confirmed correct anatomical alignment and stable fixation. At the 1-year follow-up examination, excellent fracture healing was observed at the surgical site, and the patient had started weight-bearing functional exercises (Figure 3).
Typical Case 3
A 26-year-old male patient presented with distal fractures of the left tibia and fibula, treated with ORIF using biodegradable plate and screws. At the 1-year follow-up examination, excellent fracture healing was observed at the surgical site, with visible screw tracts left by absorbable screws. The patient had started weight-bearing functional exercises, and no second surgery was required for plate removal (Figure 4).
Discussion
Titanium and biodegradable implants both provide effective fracture stabilization, but each has distinct advantages and limitations. In this retrospective cohort study, the most significant finding is that biodegradable PLA/PGA with magnesium alloys implants significantly reduced the burden of secondary interventions compared to conventional titanium fixation. Our analysis reveals a distinct clinical trade-off: while titanium implants provided rigid fixation, they were associated with a high rate of hardware prominence (45.0%), leading to a significantly higher frequency of elective implant removal (17.5%). In contrast, the biodegradable cohort experienced zero elective removals (P = 0.014). This is consistent with findings from prior studies, which have similarly reported higher rates of hardware removal in patients treated with metallic implants.14 The clinical implication of this finding is substantial. Recent large-scale meta-analyses have highlighted that elective hardware removal is not a benign procedure; it is associated with significant healthcare costs, a risk of wound complications, and a prolonged recovery period for patients.15 By eliminating the need for this routine secondary surgery, biodegradable implants not only improve patient satisfaction but may also reduce the overall economic burden on the healthcare system, a benefit that is increasingly prioritized in modern orthopedics.
Patient demographics in this study align with findings from previous research. The mean patient age was 42.6 ± 16.03 years, with a male predominance (63.9%), most fractures affecting the lower limbs accounting for titanium group 75.6% while in the biodegradable it was recorded 60.6%. Weight-bearing fractures accounted for 75.0% in the titanium group and 73.0% in the biodegradable group, emphasizing the importance of implant durability in load-bearing bones. Comparable demographic patterns have been reported in other studies16 and this similarity suggests our cohort is representative strengthening the generalizability of our findings.
A key criticism of biodegradable fixation in literature is its limited mechanical strength compared to titanium, particularly in weight-bearing bones. Biomechanical analyses have demonstrated higher stress concentrations in biodegradable implants, leading to increased failure risks in unstable fractures.17 New biomechanical data has further elucidated this limitation. Studies comparing magnesium-based implants to titanium have shown that while magnesium offers superior load-sharing properties (reducing stress shielding), it possesses significantly lower torsional stiffness.18 This makes biodegradable implants vulnerable to failure in fractures subject to rotational forces, such as spiral fractures of the tibial shaft. Our study addresses this by explicitly defining the clinical indications for each implant. As noted in our methodology, titanium was preferentially selected for diaphyseal (shaft) fractures where these bending and torsional forces are highest. Conversely, biodegradable implants were utilized primarily for metaphyseal and peri-articular fractures (eg, distal tibia, malleolus). In these anatomical regions, the soft tissue envelope is thin, and conventional metal plates frequently cause symptomatic prominence requiring removal. Our stratified analysis confirms this benefit: even among weight-bearing patients, those with biodegradable implants reported significantly lower palpability rates (11.1%) compared to the titanium group (53.3%, P < 0.05). This supports the clinical strategy of using biodegradable implants for articular fractures to avoid the second trauma of implant removal surgery.19,20
Moreover, biodegradable implants offered superior comfort, mechanical stability remains a valid concern. In our weight-bearing subgroup, we observed three cases (9.1%) of refracture or loss of reduction in the biodegradable group, compared to zero in the titanium group (P = 0.193). This finding aligns with concerns raised by other authors regarding the time-dependent loss of strength in degradable polymers and the potential for implant failure.21 It is also important to consider the degradation behavior of magnesium. Recent radiographic analyses have identified that magnesium-based screws can exhibit transient radiolucent zones around the implant during the early degradation phase.22 While typically benign, these zones may temporarily reduce screw pull-out strength before bone remodeling is complete. This underscores the need for strict patient compliance with protected weight-bearing protocols during the first 6–8 weeks. Despite these mechanical challenges, satisfactory clinical and radiographic consolidation was observed in the majority of patients. Previous clinical trials suggest that the magnesium component in these implants releases ions that promote angiogenesis and osteogenesis.23,24 This biological advantage is supported by recent studies demonstrating that magnesium degradation products actively stimulate the CGRP/VEGF pathway, potentially offsetting the lower mechanical stiffness of the polymer by accelerating the biological cascade of healing.25
Critics of biodegradable systems often cite the complexity of intraoperative contouring as a disadvantage. However, our results showed no significant difference in operative time between the biodegradable and titanium groups in either weight-bearing (133.1 vs 147.7 min, P = 0.369) or non-weight-bearing (126.7 vs 112.5 min, P = 0.519) cohorts. This suggests that with the technique of hot-water contouring described in our methods, biodegradable plates can be applied with similar efficiency to standard metallic hardware, effectively removing “surgical difficulty” as a barrier to their adoption.
Overall, biodegradable implants reduce the need for hardware removal, improving patient outcomes and lowering surgical burden. However, fracture type and anatomical location clearly influence implant performance. High-load-bearing fractures may still require titanium implants due to their superior mechanical stability. However, our results show that biodegradable implants significantly reduce the need for secondary surgeries and plate palpability which is a major source of patient discomfort. Our findings provide a practical recommendation for clinicians: for patients with weight bearing fractures where implant palpability is primary concern, these modern biodegradable implants may present a clinically effective alternative to titanium.
This study has some limitations that must be acknowledged. First, as a retrospective, single center study the findings of the study are susceptible to selection bias as the choice of implant (titanium vs biodegradable) was based on surgeon preference and clinical judgment rather than randomization. Second, the relatively small sample size particularly within the weight-bearing and non-weight-bearing subgroups limits the study statistical power which may have prevented us from detecting more subtle differences in outcomes. Finally, the follow-up duration was not long enough to fully assess the long-term degradation behavior of the biodegradable implants meaning that late-onset complications which require multi-year observation may not have been captured.
Acknowledging these limitations, our study nonetheless provides important clinical evidence that biodegradable implants are a viable alternative to titanium, offering significant advantages in reducing implant palpability and the need for secondary surgeries. Future large-scale, randomized controlled trials with long-term follow-up are necessary to confirm these findings and more comprehensively evaluate the long-term performance of these materials.
Conclusion
In this cohort, biodegradable PLA/PGA magnesium-reinforced implants were associated with being a viable alternative to titanium implants for the fixation of metaphyseal and peri-articular fractures. They offer a clear advantage in reducing implant palpability and eliminating the need for elective hardware removal surgery. However, due to the lower mechanical strength compared to titanium implants, patient selection is critical. Biodegradable fixation is best reserved for fractures with good bony apposition in metaphysis, whereas titanium remains the preferred choice for diaphyseal fractures requiring high mechanical stability. These findings are limited by the retrospective design, inherent confounding by indication, and follow-up constraints; future large-scale research is required before drawing definitive practice recommendations.
Declaration of Generative AI and AI-Assisted Technologies in Writing Progress
During the preparation of this work author(s) used ChatGPT-5 in order to linguistic amendments. After using the tool/service the author(s) reviewed and edited the content of the publication. This work has been reported in line with the TITAN criteria.
Data Sharing Statement
The data that supports the findings of this study are available from the corresponding author upon reasonable request.
Ethics Approval and Consent to Participate
All procedures performed in this study involving human participants were in accordance with the ethical standards of the institutional and national research committee and with the 1975 Helsinki Declaration and its later amendments or comparable ethical standards. In order to comply with the ethical considerations in this research, the information of the participants was kept confidential and other people were not able to access this information. The names and surnames of the participants were not used for data collection, and data collection was done after obtaining the code of ethics from Xinjiang Medical University. The study was approved by the Medical Ethical Committee of the First Affiliated Hospital of Xinjiang Medical University (K202506-16).
Consent for Publication
Written informed consent was signed from the three participants of the case studies before starting the study.
Acknowledgments
We would like to express our gratitude to the respected mentors and advisors, the respected President of The First Affiliated Hospital of Xinjiang Medical University, the participants in the study, and all people who helped us in conducting this study.
Funding
This study was funded by the Tianshan Talent Technology Innovation Leading Talent- High-Level Leading Talent Project (2022TSYCLJ0026).
Disclosure
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
References
1. Zhou S, Zheng Z, Zhang C, et al. LncRNA LINC01123-mediated impaired fracture healing through miR-134-5p/XIAP axis. J Orthop Surg Res. 2025;20(1):790. doi:10.1186/s13018-025-06167-3
2. Shichman I, Shaked O, Factor S, Elbaz E, Khoury A. Epidemiology of fractures sustained during electric scooter accidents: a retrospective review of 563 cases. J Bone Joint Surg Am. 2021;103(12):1125–14. doi:10.2106/JBJS.20.01746
3. Dimet-Wiley A, Golovko G, Watowich SJ. One-year postfracture mortality rate in older adults with hip fractures relative to other lower extremity fractures: retrospective cohort study. JMIR Aging. 2022;5(1):e32683. doi:10.2196/32683
4. Ryan DJ, Minhas SV, Konda S, Catalano LW. Surgical site infection after open upper extremity fracture and the effect of urgent operative intervention. J Orthop Trauma. 2020;34(5):258–262. doi:10.1097/BOT.0000000000001700
5. Kambhampati SBS, Rajagopalan S, Abraham VT, Poduval M, Maini L. Implant design and its applications in the fixation of osteoporotic bones: newer technologies in nails, plates and external fixators. Indian J Orthop. 2024;59(3):280–293. doi:10.1007/s43465-024-01295-0
6. Barber CC, Burnham M, Ojameruaye O, McKee MD. A systematic review of the use of titanium versus stainless steel implants for fracture fixation. OTA Int. 2021;4(3):e138. doi:10.1097/OI9.0000000000000138
7. Kim T, See CW, Li X, Zhu D. Orthopedic implants and devices for bone fractures and defects: past, present and perspective. Eng Regen. 2020;1:6–18. doi:10.1016/j.engreg.2020.05.003
8. Li J, Qin L, Yang K, et al. Materials evolution of bone plates for internal fixation of bone fractures: a review. J Mater Sci Technol. 2020;36:190–208. doi:10.1016/j.jmst.2019.07.024
9. Ramya M. Advances in biodegradable orthopaedic implants: optimizing magnesium alloy corrosion resistance for enhanced bone repair. Biomed Mater Devices. 2025;3(1):396–414. doi:10.1007/s44174-024-00208-x
10. Hassan KM, Mohamed AM, Eissa HA. Biodegradable plates versus titanium mini-plates for fixation of metacarpal and phalangeal fractures. Egypt J Plast Reconstr Surg. 2020;43(3):581–589.
11. Zhou K, He X, Tao X, Pan F, Yang H. A biomechanical matched-pair comparison of two different locking plates for tibial diaphyseal comminuted fracture: carbon fiber-reinforced poly-ether-ether-ketone (CF-PEEK) versus titanium plates. J Orthop Surg Res. 2020;15(1):558. doi:10.1186/s13018-020-02096-5
12. Kim DY, Sung IY, Cho YC, Park EJ, Son JH. Bioabsorbable plates versus metal miniplate systems for use in endoscope-assisted open reduction and internal fixation of mandibular subcondylar fractures. J Craniomaxillofac Surg. 2018;46(3):413–417. doi:10.1016/j.jcms.2017.12.026
13. Dhillon MS, Prabhakar S, Prasanna C. Preliminary experience with biodegradable implants for fracture fixation. Indian J Orthop. 2008;42(3):319–322. doi:10.4103/0019-5413.41856
14. Li ZH, Yu AX, Guo XP, Qi BW, Zhou M, Wang WY. Absorbable implants versus metal implants for the treatment of ankle fractures: a meta-analysis. Exp Ther Med. 2013;5(5):1531–1537. doi:10.3892/etm.2013.1017
15. Fenelon C, Murphy EP, Galbraith JG, Kearns SR. The burden of hardware removal in ankle fractures: how common is it, why do we do it and what is the cost? A ten-year review. Foot Ankle Surg. 2019;25(4):546–549. doi:10.1016/j.fas.2018.05.006
16. Golubev VG, Starostenkov AN. Operative technique features in application of bioabsorbable implants for limb fractures treatment. Surg Pract. 2017;(2):5–13.
17. Zhao D, Witte F, Lu F, Wang J, Li J, Qin L. Current status on clinical applications of magnesium-based orthopaedic implants: a review from clinical translational perspective. Biomaterials. 2017;112:287–302. doi:10.1016/j.biomaterials.2016.10.017
18. Ahemad AZ, Rattan V, Jolly SS, Kalra P, Sharma S. Biomechanical comparison of magnesium bioresorbable and titanium lag screws for mandibular symphysis fracture fixation: a finite element analysis. J Stomatol Oral Maxillofac Surg. 2025;126(5S):102383. doi:10.1016/j.jormas.2025.102383
19. Yerit KC, Enislidis G, Schopper C, et al. Fixation of mandibular fractures with biodegradable plates and screws. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2002;94(3):294–300. doi:10.1067/moe.2002.122833
20. Zailai A, Alenizi T, Sbitan R, et al. Comparison of biodegradable versus titanium fixation systems in mandibular fractures: systematic review and meta-analysis. Surgeries. 2026;7(1):20. doi:10.3390/surgeries7010020
21. Hu M, Li M, Ma R, et al. Biomechanical analysis of titanium-alloy and biodegradable implants in dual plate osteosynthesis for AO/ASIF type 33-C2 fractures. Heliyon. 2024;10(4):e26213. doi:10.1016/j.heliyon.2024.e26213
22. Waelti SL, Markart S, Willems EP, et al. Radiographic features of magnesium-based bioabsorbable screw resorption in paediatric fractures. Pediatr Radiol. 2022;52(12):2368–2376. doi:10.1007/s00247-022-05383-x
23. Sun J, Li Z, Liu S, Xia T, Shen J. Biodegradable magnesium screw, titanium screw and direct embedding fixation in pedicled vascularized iliac bone graft transfer for osteonecrosis of the femoral head: a randomized controlled study. J Orthop Surg Res. 2023;18(1):523. doi:10.1186/s13018-023-04012-z
24. Dachasa K, Chuni Aklilu T, Gashaw Ewnete B, Mosisa Ejeta B, Fufa Bakare F. Magnesium-based biodegradable alloy materials for bone healing application. Adv Mater Sci Eng. 2024;2024:1325004. doi:10.1155/2024/1325004
25. Huang J, Wu J, Liu D, Gao P. Advances in magnesium metal and its alloys for promoting angiogenesis. J Biomed Mater Res B Appl Biomater. 2025;113(11):e35671. doi:10.1002/jbm.b.35671
© 2026 The Author(s). This work is published and licensed by Dove Medical Press Limited. The
full terms of this license are available at https://www.dovepress.com/terms
and incorporate the Creative Commons Attribution
- Non Commercial (unported, 4.0) License.
By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted
without any further permission from Dove Medical Press Limited, provided the work is properly
attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.